Biochemical Assay Kits Documentation

Solarbio manufactures over 200 biochemical assay kits across major assay categories. All kits include validated protocols, lot-specific COA, and quality control data.

Scope and Quality Commitment

Solarbio assay kits are designed for quantitative determination of biomarkers, enzyme activities, and metabolites in biological samples including serum, plasma, tissue homogenates, cell lysates, and plant extracts. Each kit is manufactured to ISO 9001:2015 standards with lot-specific QC data including standard curves, precision, and recovery.

Why Choose Solarbio Assay Kits

  • 200+ validated kits covering the most commonly used biomarkers in academic and clinical research
  • All kits include pre-measured standards, ready-to-use reagents, and detailed protocols
  • Detection methods compatible with standard 96-well plate readers (colorimetric, fluorometric)
  • Intra-assay CV <5%, inter-assay CV <10% across all kit categories
  • Lot-specific standard concentration values provided — no need to create custom standards
  • Competitive pricing: typically 30–60% below comparable kits from Sigma-Aldrich or Abcam
  • Technical support from application scientists for protocol adaptation to new sample types

Assay Categories

Category Example Targets Detection Sample Types Typical Assays/Kit SKU Count
Oxidative Stress SOD, CAT, MDA, GSH, GSSG, GPx, GR, GST, T-AOC, ROS, MPO, NO, H₂O₂, XOD Colorimetric, fluorometric (14 kits) Serum, tissue, lysate, RBC 100/plate 25+
Metabolism ATP, glucose, triglyceride, cholesterol, lactate, pyruvate kinase Spectrophotometric (6 kits) Cells, tissue, bacteria, serum 100/plate 15+
Hepatotoxicity & Clinical Chemistry ALT, AST, ALP, GGT, LDH, creatinine, BUN Endpoint colorimetric (7 kits) Serum, plasma, urine 100/plate 12+
Inflammation MPO, NO, iNOS, XOD, lipase Colorimetric, kinetic (5 kits) Tissue, neutrophil lysate, serum 100/plate 10+
Protein Quantification BCA, Bradford, Lowry, UV A₂₈₀ Colorimetric, UV (4 kits) All sample types 96/plate 6+
Enzyme Activity Dehydrogenases, kinases, peroxidases, proteases, lysozyme Varied (20+ kits) Tissue, cell lysate 100/plate 30+
Plant Biology Chlorophyll, proline, nitrate reductase, H₂O₂, MDA (plant) Spectrophotometric (6 kits) Plant tissue 100/plate 12+
Lipid Metabolism Triglycerides, cholesterol, HDL, LDL, free fatty acids Enzymatic colorimetric Serum, tissue 100/plate 10+

Common Kit Components

Component Description Quality Specification
Standard Lyophilized or liquid, known concentration Lot-specific value ±2%
Buffer A (Reaction buffer) Optimized pH and ionic strength ±0.1 pH unit
Buffer B (Stop solution) Acidic or basic stop solution Concentration ±5%
Substrate Chromogenic or fluorogenic substrate Purity >99% by HPLC
Enzyme (positive control) Recombinant or tissue-purified Activity verified per lot
Microplate 96-well clear or UV-transparent plate Certified flat-bottom
Protocol booklet Step-by-step with calculation formulas Revision-controlled

Analytical Performance Specifications

Parameter Colorimetric Kits Fluorometric Kits Kinetic Enzyme Assays
Limit of detection (LOD) 0.01–1.0 μmol/L (varies by target) 0.001–0.1 μmol/L 0.01–0.5 U/L
Linear range 2–3 orders of magnitude 3–4 orders of magnitude 1–100 mU/mL
Intra-assay CV <5% <5% <3%
Inter-assay CV <10% <10% <8%
Spike recovery 90–110% 85–115% 90–110%
Assay time 10–60 min 15–45 min 5–30 min (kinetic)
Sample volume required 10–50 µL 5–25 µL 10–50 µL
High-throughput compatibility 96-well plate 96-well plate 96-well plate

Instrument Compatibility

Solarbio assay kits are validated on the following microplate readers:

Instrument Model Absorbance Mode Fluorescence Mode Kinetics Mode
BioTek Epoch/Synergy Yes (Filter-based) Yes Yes
Thermo Scientific Multiskan GO Yes (Monochromator) No Yes
Molecular Devices SpectraMax Yes Yes Yes
BMG Labtech CLARIOstar Yes Yes Yes
Tecan Infinite M200/M Nano Yes Yes Yes

Quality Control Per Lot

Each kit lot is tested against: - Standard curve linearity (R² > 0.99 required for release) - Low-concentration standard recovery (90–110% of expected value) - High-concentration standard recovery (90–110% of expected value) - Blank absorbance (must be below 0.10 OD at detection wavelength) - Positive control activity (within 2 SD of established mean) - Intra-plate precision (CV <5% for replicates) - Visual inspection for reagent clarity (no precipitate or discoloration)